Basic Info
  • Model NO.: C1KS
  • Type: On-line
  • Wave Form: Pures Sinewave
  • Warrenty: One Year
  • Certificate: CE
  • Transfer Time: Zero
  • Shape: Castle
  • Specification: CE, ISO9001
  • HS Code: 85044020
  • Phase: Single Phase
  • Protection: Overvoltage
  • Battery: Lead Acid Free Battery
  • Range of Application: Telecom, Sensitive Electronic Equipement
  • Display: LED/LCD
  • Software: Support
  • Trademark: MUST
  • Origin: Shenzhen, China
Product Description
Features:

1. Sine-wave output:
True sine-wave output with less than 3% THD.

2. Double Conversion Design:
Zero transfer/ complete isolation of input AC.

3. UPS Monitoring Software:
Powerful true RS232 communication via the enclosed software
To manage and safely shutdown operating systems.

4. Network RJ45/11 protection:
Complete powerful network and phone line surge protection.

5. AC Surge Suppressor:
Powerful multi-stage surge components that exceed IEEE requirements.

6. SNMP Slot Option:
Allows for remote monitoring and control via.

7. Sleep Mode:
Worry free battery management. The unit turns itself off after ten seconds to conserve battery
Power when no power needs are detected.

8. Battery level indicators:
LED''s indicate battery levels.

9. Load Sensing:
The incorporated LED load indicators allow IT professionals to manage backup time and balance power loads.

10. Low Battery indicators:
The low battery level indicator will warn of eminent UPS shutdown two full minutes before unit shuts down.

11. Replace Battery indicators:
A preventative measure that indicates when batteries must be replaced to prevent server crashes.
Online UPS China Manufacture 1kVA
body {background: #C0EBC6 !important;}div {background-color: #C0EBC6 !important;}header,nav,table,th,tr,td,dl,ul,li,ol,fieldset,form,h1,h2,h3,h4,h5,h6,pre {background: transparent !important;}* {color: #363636 !important;}a:link,a:link *,a:link:hover,a:link:hover *,a:link:active,a:link:active * {color: #3E3822 !important;}a:visited,a:visited *,a:visited:hover,a:visited:hover *,a:visited:active,a:visited:active * {color: #0060BF !important;}

body {background: #C0EBC6 !important;}div {background-color: #C0EBC6 !important;}header,nav,table,th,tr,td,dl,ul,li,ol,fieldset,form,h1,h2,h3,h4,h5,h6,pre {background: transparent !important;}* {color: #363636 !important;}a:link,a:link *,a:link:hover,a:link:hover *,a:link:active,a:link:active * {color: #3E3822 !important;}a:visited,a:visited *,a:visited:hover,a:visited:hover *,a:visited:active,a:visited:active * {color: #0060BF !important;}
Model
 
C1KS
 
C2KS
 
C3KS
 
Rated Power
 
VA/W
 
1kVA / 0.7kW
 
2kVA / 1.4kW
 
3kVA / 2.1kW
 
Input
 
Nominal Voltage
 
220VAC
 
Voltage Range
 
115 ~ 300VAC
 
Frequency Range
 
46 ~ 54Hz(default), user adjustable within 40~60Hz
 
Power Factor
 
0.97
 
Connection
 
IEC320 -10A inlet
 
IEC320 -16A inlet
 
Output
 
Voltage
 
220VAC ± 2%
 
Frequency
 
46~54Hz or 50Hz ± 0.2Hz (Line mode)
50Hz ± 0.2Hz ( Battery mode)
 
Waveform
 
Pure Sine Wave
 
Distortion
 
3%
 
4%
 
Overload Capability
 
108% ~ 150% for 30 sec., ³150% for 300 ms
 
Current Crest Ratio
 
3:1
 
Connections
 
IEC320 -10A *4
 
IEC320 -10A *6
 
IEC320 -10A *3 and
Terminal Block
 
Battery
 
 
Type
 
Sealed, Maintenance free, Lead-Acid
 
Nominal DC Voltage
 
36VDC
 
96VDC
 
Back-up Time
 
Depends on the capacity of the external battery bank
 
Connection
 
External Battery Socket
 
Bypass
 
 
Automatic Transfer
 
On overload and UPS failure
 
Before UPS Power-on
 
Default "NO", user adjustable to "YES"
 
Voltage Range
 
80 ~ 264VAC (Default), user adjustable within 80 ~ 286VAC
 
Transfer Time
 
0 ms; less than 4 ms from inverter to bypass and vice versa
 
LED Indicators
 
Status
 
Load level / Battery level, Battery , Utility Power, Inverter, Bypass, Overload, Fault
 
Audible Alarm
 
Bypass, On battery mode, Battery low, Overload, Fault
 
Acoustic Noise
 
At 1 meter distance
 
45 dBA
 
50 dBA
 
Communications
 
DB-9 Port
 
RS-232 Serial Interface
 
Intelligent Slot
 
Options: WebPower, AS400 Card or WinPower CMC
 
Network Surge Protection
 
RJ45 I/O port available for 10 base-T network or Fax/Modem
 
Environmental
 
Operating Temperature
 
0 ~ 40°C
 
Operating Humidity
 
20 ~ 90% non-condensing
 
Weight
 
Net (Kg)
 
7
 
13.5
 
14
 
Dimensions
 
W x D x H (mm)
 
145 x 400 x 220
 
192 x 460 x 348
 