Home » Product List » Online ups » Online High Frequency UPS (1-10KVA)
Product Details
Online High Frequency UPS (1-10KVA)
| Packing: | Carton |
|---|---|
| Model NO.: | C1KVA--C10KVA |
| Standard: | CE, FCC, ISO9001: 2000 |
| Productivity: | 8, 000 pcs/month |
| HS Code: | 85044020 |
| Trademark: | SANTAKUPS |
| Origin: | ShenZhen, China |
| Transportation: | By sea or by air |
Descriptions:
1. Sine-wave output:
True sine-wave output with less than 3% THD.
2. Double Conversion Design:
Zero transfer/ complete isolation of input AC.
3. UPS Monitoring Software:
Powerful true RS232 communication via the enclosed software
to manage and safely shutdown operating systems.
4. Network RJ45/11 protection:
Complete powerful network and phone line surge protection.
5. AC Surge Suppressor:
Powerful multi-stage surge components that exceed IEEE requirements.
6. SNMP Slot Option:
Allows for remote monitoring and control
7. Sleep Mode:
Worry free battery management. The unit turns itself off after ten seconds to conserve battery
power when no power needs are detected.
8. Battery level indicators:
LED''s indicate battery levels.
9. Load Sensing:
The incorporated LED load indicators allow IT professionals to manage backup time and balance
power loads.
10. Low Battery indicators:
The low battery level indicator will warn of eminent UPS shutdown two full minutes before unit shuts
down.
11. Replace Battery indicators:
A preventative measure that indicates when batteries must be replaced to prevent
server crashes.
| Product Series | CASTLE | |||
| Model | C1K | C2K | C3K | |
| Rated Power | BA / BT | 1 kVA / 0.7k BT | 2kVA / 1.4 kBT | 3kVA / 2.1kBT |
| Input | Nominal Voltage | 220B AC | ||
| Voltage Range | 115 ~ 300B AC | |||
| Frequency Range | 46~54Hz(default), user adjustable within 40~60Hz | |||
| Power Factor | 0.97 | |||
| Connection | IEC320 -10A inlet | IEC320 -16A inlet | ||
| Output | Voltage | 220B AC ± 2% | ||
| Frequency | 46~54Hz or 50Hz ± 0.2Hz (Line mode) 50Hz ± 0.2Hz ( Battery mode) | |||
| Waveform | Sine Wave | |||
| Distortion | 3% | 4% | ||
| Overload Capability | 108%~150% for 30 sec., ³150% for 300 ms | |||
| Current Crest Ratio | 3:1 | |||
| Connections | IEC320 * 4 | IEC320 * 6 | IEC320 * 3 and Terminal Block | |
| Battery | Type | Sealed, Maintenance free, Lead-Acid (Panasonic) | ||
| Quantity | 3 pieces | 8 pieces | ||
| Back-up Time (Full load) | 5 min | 9 min | 5 min | |
| Recharge Time | 5 hrs to 90% of capacity after full load discharge | |||
| Bypass | Automatic Transfer | on overload and UPS failure | ||
| Before UPS Power-on | Default “NO”, user adjustable to “YES” | |||
| Voltage Range | 80~264B AC (Default), user adjustable within 80~286B AC | |||
| Transfer Time | 0 ms; less than 4 ms from inverter to bypass and vice versa | |||
| LCD Indicators | Status | Load level / Battery level, Battery , Utility Power, Inverter, Bypass, Overload, Fault | ||
| Audible Alarm | Bypass, On battery mode, Battery low, Overload, Fault | |||
| Acoustic Noise | At 1 meter distance | 45 dBA | 50 dBA | |
| Communications | DB-9 Port | RS-232 Serial Interface | ||
| Intelligent Slot | Options: WebPower, AS400 Card or WinPower CMC | |||
| Network Surge Protection | RJ45 I/O port available for network or Fax/Modem | |||
| Environmental | Operating Temperature | 0 ~ 40°C | ||
| Operating Humidity | 20 ~ 90% non-condensing | |||
| Weight | Net (Kg) | 13 | 31.5 | 32 |
| Dimensions | W x D x H (mm) | 145 x 400 x 220 | 192 x 460 x 348 | |
Inquiry Basket (




