Battery Charger, Sealed Lead Acid Battery Charger, Car Battery Charger manufacturer / supplier in China, offering Battery Charger DC24V/20A, Lithuania 2kVA Uninterruptable Power Supply with Battery 2kVA UPS Power Back-up, Uninterruptable Power Supply 2kvawith Inbuilt Battery UPS in Russian Market and so on.

(/ )

Supplier Homepage Product Others Battery Charger DC24V/20A

Battery Charger DC24V/20A

FOB Price: US $48.5 / Piece
Min. Order: 500 Pieces
Min. Order FOB Price
500 Pieces US $48.5/ Piece
Get Latest Price
Production Capacity: 10, 000 PCS/Month
Transport Package: Gift Box
Payment Terms: L/C, Money Gram

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: DC12V/40A, DC24V/20A
  • Specification: CE, FCC, ISO9001: 2000
  • HS Code: 85044020
  • Trademark: MUST
  • Origin: Shenzhen, China
Product Description
Features descriptions:

1. Three stages variable charging voltage algorithm by timing for maximizing the battery lifetime

2. Large charging capacity design (40A for 12Vdc mode, 20A for 24Vdc mode) for reduce the charge time

3. Selectable charging currents based on connected battery capacity for extending battery lifetime with optimized charging current

4. Multiple voltage charging design for protecting diverse types of batteries of Flooded Lead-Acid, Gel, AGM chemistries batteries

5. Wider input voltage range from 90Vac to 280Vac for universal input

6. High AC to DC converting efficiency design (higher than 80%)

7. Smart fan control -Build-in fan control firmware for controlling fan on/off status bases on charger operating mode. When the battery is charged, the fan will stop to reduce the noise and also extend the fan lifetime.
Input
 
Input Voltage
 
180-280VAC full performance
 
90-180VAC automatically derate to 50% of full load current
 
Frequency
 
40Hz to 70Hz
 
Nominal Input C urrent at R ated O utput
 
<9Aac
 
Voltage M easurement A ccuracy
 
±8Vac
 
Frequency M easurement A ccuracy
 
±1Hz
 
Output
 
Nominal V oltage
 
12/24Vdc manual adjustable
 
Output C urrent
 
Input voltage 180-280V ,
output current 40A for 12V mode
output current 2 0A for 24V mode
 
Input voltage 90-180V ,
output current 2 0A for 12V mode
output current 1 0A for 24V mode
 
Rated O utput C urrent
 
Manual adjustable
 
Current A ccuracy
 
± 6% of full rated output current @25°C, for target currents across the range from 10% rated output (for absorption exit criteria accuracy) to the current limit setpoint.
 
Load R egulation
 
1.5%
 
Current L imit
 
40-44Amp
 
Dead- B attery C harging
 
8-14.9Vdc at 100% of rated output current
 
8-29.8Vdc at 100% of rated output current
 
Selectable Battery T ype
 
Flooded Lead-Acid, Gel, AGM, manual adjustable
 
Parallel O utputs
 
Maximum two charger units connection in parallel
 
Efficiency
 
80%
 
  Protection
 
Input O ver V oltage
 
Unit must be safe for input voltage up to 300VacRMS (and up to 430Vpeak), need not be operating. Above this level the unit may be damaged.
 
Reverse B attery P olarity P rotection
 
Non-destructive reverse battery polarity protection with fuses. Unit shall not sustain damage and shall meet all specifications after fuse replacement.
 
Input Under-voltage
 
Unit must not be damaged for all input voltages from 0-300Vac.   Shutdown or input current limit or other means may be applied when input voltage is out of normal operating range.
 
Output over voltage
12/24V mode
 
Unit will shut down if Vcharging > Vcharging (target) + 1.0Vdc for more than 2 seconds; unit will restart when voltage <= Vcharging (target) for more than 2 seconds.
For battery OVP the unit will restart in the same stage.
 
Unit will shut down if Vcharging > Vcharging (target) + 1.5Vdc for more than 2 seconds; unit will restart when voltage <= Vcharging (target) for more than 2 seconds.
For battery OVP the unit will restart in the same stage.
 
Charger over temperature protection  
 
The internal temperatures of the charger will be measured by NTC. Based on these measurements, unit will shut down if the temperature exceeds 60°C. Unit will restart when environment temperature cools to 55 'C
 
  Environmental
 
Operation temperature
 
Nominal a mbient t emperature: 25'C
Operating a mbient t emperature r ange: -10°C to 60'C
Full performance: -10'C to +40'C
Derated mode: +40'C to +60'C
Automatically s hut d own when over 60 'C
 
Relative humidity
 
5 ~95% without condensation
 
Noise
 
Unit requirements: below 50dB (A) measured at 1 m distance with fan full working.
 
Storage C onditions Temperature
 
-20'C to +80'C
 
Cooling
 
Fan Cooling with Smart fan control
 
Safety
 
CE
 
  Mechanical
 
Dimension (D x W x H ) mm
 
224 x 255 x 80
 
Unit Weight
 
1.7 kg
 